Our Datacenter
Datacenter Features
Compliance
Compliant for controls:
HITRUST CSF
PCI DSS
HIPAA
Audited annually for:
EU-US Privacy Shield Framework
SOC 1 Type II, SOC 2 Type II, SOC 3
NIST 800-53, ITAR, SSAE 18
Connectivity
3 Tbps total network capacity
Carrier-Neutral blended and proactively managed and monitored
Redundant, automatically re-routed connections from 10 Mbps to 10 Gbps
Proactive Layer 3 and Layer 4 DDoS protection
Power and Cooling
2N UPS redundancy
529 kW critical load UPS capacity
150+ W/SF power density
Hot/cold aisle configuration
100% power SLA
2.0 PUE rating
Flexible Solutions
CarbonLogic provides highly flexible and scalable solutions to fit any client’s needs.
Server Co-location
Private Cloud (compliant multi VM)
Public Cloud (individual VMs)
Shared Hosting (managed website hosting)
Disaster Recovery
Our secure location is an ideal choice for a DR installation. If you need extended redundancy for disaster recovery we have a secondary geographically dispersed datacenter site in Colorado.
Network Operations Center (NOC)
Our on-site NOC is manned 7 days a week by highly experienced, level 1, 2 and 3 staff with both on-site and remote hands capability, available 24×7, every day of the year.
System Monitoring
We have comprehensive monitoring of all core infrastructure. These include power, environmental and networking facilities, allowing our staff to respond immediately to any abnormal conditions. Our monitoring system can be extended to cover client equipment and services allowing for rapid remote-hands or consulting services, and immediate client notification by SMS and email.
Private Networking/Cross Connected Circuits
CarbonLogic has Carrier-neutral blended, and proactively managed and monitored, IP bandwidth. Private nodes are available to provide physically secure, private backnet capabilities via EVC (Ethernet Virtual Connection) for any co-location client. We can also cross-connect client owned circuits of any type desired (DS1s, DS3s, etc), delivered over either fiber or copper.
Fire Detection & Suppression
Fires in a datacenter are rare, but CarbonLogic is prepared. We have a VESDA early detection system to detect issues before there is smoke. We also have a multi-zone, double throw, aqueous fire suppression system with high-temp sprinkler heads. The system is non-pre charged, which means the lines are filled with compressed air under normal conditions, eliminating accidental release if damage is done to a sprinkler head. FM-200 is used before water and causes no damage.